###### ipmi.5 ###### .. highlight:: perl **** NAME **** \ **ipmi**\ - a table in the xCAT database. ******** SYNOPSIS ******** \ **ipmi Attributes:**\ \ *node*\ , \ *bmc*\ , \ *bmcport*\ , \ *taggedvlan*\ , \ *bmcid*\ , \ *username*\ , \ *password*\ , \ *comments*\ , \ *disable*\ *********** DESCRIPTION *********** Settings for nodes that are controlled by an on-board BMC via IPMI. **************** ipmi Attributes: **************** \ **node**\ The node name or group name. \ **bmc**\ The hostname of the BMC adapter. \ **bmcport**\ In systems with selectable shared/dedicated ethernet ports, this parameter can be used to specify the preferred port. 0 means use the shared port, 1 means dedicated, blank is to not assign. .. code-block:: perl The following special cases exist for IBM System x servers: - For x3755 M3 systems, 0 means use the dedicated port, 1 means shared, blank is to not assign. - For certain systems which have a mezzaine or ML2 adapter, there is a second value to include: For x3750 M4 (Model 8722): 0 2 1st 1Gbps interface for LOM 0 0 1st 10Gbps interface for LOM 0 3 2nd 1Gbps interface for LOM 0 1 2nd 10Gbps interface for LOM For x3750 M4 (Model 8752), x3850/3950 X6, dx360 M4, x3550 M4, and x3650 M4: 0 Shared (1st onboard interface) 1 Dedicated 2 0 First interface on ML2 or mezzanine adapter 2 1 Second interface on ML2 or mezzanine adapter 2 2 Third interface on ML2 or mezzanine adapter 2 3 Fourth interface on ML2 or mezzanine adapter For Dell systems, a second and third values can also be used: 1st value: 0 = shared / 1 = dedicated 2nd value shared LOM (1-4) (0 or no value means first available LOM) 3rd value: failover LOM (1-4) (0 means no failover, no value means all LOMs) 0 Shared with first available interface, failover all LOMs (catch all mode) 0 1 Shared with LOM1, failover all LOMs 0 1 2 Shared with LOM1, failover LOM2 0 2 0 Shared with LOM2, no failover 1 Dedicated \ **taggedvlan**\ bmcsetup script will configure the network interface of the BMC to be tagged to the VLAN specified. \ **bmcid**\ Unique identified data used by discovery processes to distinguish known BMCs from unrecognized BMCs \ **username**\ The BMC userid. If not specified, the key=ipmi row in the passwd table is used as the default. \ **password**\ The BMC password. If not specified, the key=ipmi row in the passwd table is used as the default. \ **comments**\ Any user-written notes. \ **disable**\ Set to 'yes' or '1' to comment out this row. ******** SEE ALSO ******** \ **nodels(1)**\ , \ **chtab(8)**\ , \ **tabdump(8)**\ , \ **tabedit(8)**\