rspconfig.1

NAME

rspconfig - Configures nodes’ service processors

SYNOPSIS

rspconfig [-h | --help | -v | --version | -V | --verbose]

BMC/MPA specific:

rspconfig noderange {alert | snmpdest | community}

rspconfig noderange alert={on | enable | off | disable}

rspconfig noderange snmpdest=snmpmanager-IP

rspconfig noderange community={public | string}

BMC specific:

rspconfig noderange {ip | netmask | gateway | backupgateway | garp | vlan}

rspconfig noderange garp=time

OpenBMC specific:

rspconfig noderange {ipsrc | ip | netmask | gateway | vlan}

rspconfig noderange admin_passwd={currentpasswd,newpasswd}

rspconfig noderange autoreboot

rspconfig noderange autoreboot={0|1}

rspconfig noderange bootmode

rspconfig noderange bootmode={safe|regular|setup}

rspconfig noderange dump [-l | --list] [-g | --generate] [-c | --clear {id | all}] [-d | --download {id | all}]

rspconfig noderange gard -c|--clear

rspconfig noderange ip=dhcp

rspconfig noderange hostname

rspconfig noderange hostname={* | name}

rspconfig noderange ntpservers

rspconfig noderange ntpservers={ntpservers}

rspconfig noderange powerrestorepolicy

rspconfig noderange powerrestorepolicy={always_on|restore|always_off}

rspconfig noderange powersupplyredundancy

rspconfig noderange powersupplyredundancy={disabled|enabled}

rspconfig noderange sshcfg

rspconfig noderange thermalmode

rspconfig noderange thermalmode={default|custom|heavy_io|max_base_fan_floor}

rspconfig noderange timesyncmethod

rspconfig noderange timesyncmethod={manual|ntp}

MPA specific:

rspconfig noderange {sshcfg | snmpcfg | pd1 | pd2 | network | swnet | ntp | textid | frame}

rspconfig noderange USERID={newpasswd} updateBMC={y | n}

rspconfig noderange sshcfg={enable | disable}

rspconfig noderange snmpcfg={enable | disable}

rspconfig noderange solcfg={enable | disable}

rspconfig noderange pd1={nonred | redwoperf | redwperf}

rspconfig noderange pd2={nonred | redwoperf | redwperf}

rspconfig noderange network={[ip],[host],[gateway],[netmask]|*}

rspconfig noderange initnetwork={[ip],[host],[gateway],[netmask]|*}

rspconfig noderange textid={* | textid}

rspconfig singlenode frame={frame_number}

rspconfig noderange frame={*}

rspconfig noderange swnet={[ip],[gateway],[netmask]}

rspconfig noderange ntp={[ntpenable],[ntpserver],[frequency],[v3]}

FSP/CEC specific:

rspconfig noderange {autopower | iocap | decfg | memdecfg | procdecfg | time | date | spdump | sysdump | network}

rspconfig noderange autopower={enable | disable}

rspconfig noderange iocap={enable | disable}

rspconfig noderange time=hh:mm:ss

rspconfig noderange date=mm:dd:yyyy

rspconfig noderange decfg={enable|disable:policyname,…}

rspconfig noderange procdecfg={configure|deconfigure:processingunit:id,…}

rspconfig noderange memdecfg={configure|deconfigure:processingunit:unit|bank:id,…>}

rspconfig noderange network={nic,*}

rspconfig noderange network={nic,[IP,][hostname,][gateway,][netmask]}

rspconfig noderange network={nic,0.0.0.0}

rspconfig noderange HMC_passwd={currentpasswd,newpasswd}

rspconfig noderange admin_passwd={currentpasswd,newpasswd}

rspconfig noderange general_passwd={currentpasswd,newpasswd}

rspconfig noderange *_passwd={currentpasswd,newpasswd}

rspconfig noderange {hostname}

rspconfig noderange hostname={* | name}

rspconfig noderange --resetnet

Flex system Specific:

rspconfig noderange sshcfg={enable | disable}

rspconfig noderange snmpcfg={enable | disable}

rspconfig noderange network={[ip],[host],[gateway],[netmask] | *}

rspconfig noderange solcfg={enable | disable}

rspconfig noderange textid={* | textid}

rspconfig noderange cec_off_policy={poweroff | stayon}

BPA/Frame Specific:

rspconfig noderange {network}

rspconfig noderange network={nic,*}

rspconfig noderange network={nic,[IP,][hostname,][gateway,][netmask]}

rspconfig noderange network={nic,0.0.0.0}

rspconfig noderange HMC_passwd={currentpasswd,newpasswd}

rspconfig noderange admin_passwd={currentpasswd,newpasswd}

rspconfig noderange general_passwd={currentpasswd,newpasswd}

rspconfig noderange *_passwd={currentpasswd,newpasswd}

rspconfig noderange {hostname}

rspconfig noderange hostname={* | name}

rspconfig noderange --resetnet

FSP/CEC (using Direct FSP Management) Specific:

rspconfig noderange HMC_passwd={currentpasswd,newpasswd}

rspconfig noderange admin_passwd={currentpasswd,newpasswd}

rspconfig noderange general_passwd={currentpasswd,newpasswd}

rspconfig noderange *_passwd={currentpasswd,newpasswd}

rspconfig noderange {sysname}

rspconfig noderange sysname={* | name}

rspconfig noderange {pending_power_on_side}

rspconfig noderange pending_power_on_side={temp | perm}

rspconfig noderange {cec_off_policy}

rspconfig noderange cec_off_policy={poweroff | stayon}

rspconfig noderange {BSR}

rspconfig noderange {huge_page}

rspconfig noderange huge_page={NUM}

rspconfig noderange {setup_failover}

rspconfig noderange setup_failover={enable | disable}

rspconfig noderange {force_failover}

rspconfig noderange --resetnet

BPA/Frame (using Direct FSP Management) Specific:

rspconfig noderange HMC_passwd={currentpasswd,newpasswd}

rspconfig noderange admin_passwd={currentpasswd,newpasswd}

rspconfig noderange general_passwd={currentpasswd,newpasswd}

rspconfig noderange *_passwd={currentpasswd,newpasswd}

rspconfig noderange {frame}

rspconfig noderange frame={* | frame_number}

rspconfig noderange {sysname}

rspconfig noderange sysname={* | name}

rspconfig noderange {pending_power_on_side}

rspconfig noderange pending_power_on_side={temp | perm}

rspconfig noderange --resetnet

HMC Specific:

rspconfig noderange {sshcfg}

rspconfig noderange sshcfg={enable | disable}

rspconfig noderange --resetnet

DESCRIPTION

rspconfig configures various settings in the nodes’ service processors.

For options autopower | iocap | decfg | memdecfg | procdecfg | time | date | spdump | sysdump | network, user need to use chdef -t site enableASMI=yes to enable ASMI first.

OPTIONS

alert={on | enable | off | disable}

Turn on or off SNMP alerts.

autopower={enable | disable}

Select the policy for auto power restart. If enabled, the system will boot automatically once power is restored after a power disturbance.

backupgateway

Get the BMC backup gateway ip address.

community={public | string}

Get or set the SNMP community value. The default is public.

date=mm:dd:yyy

Enter the current date.

decfg={enable | disable:policyname,…}

Enables or disables deconfiguration policies.

frame={framenumber | *}

Set or get frame number. If no framenumber and * specified, framenumber for the nodes will be displayed and updated in the xCAT database. If framenumber is specified, it only supports single node and the framenumber will be set for that frame. If * is specified, it supports noderange and all the frame numbers for the noderange will be read from xCAT database and set to frames. Setting the frame number is a disruptive command which requires all CECs to be powered off prior to issuing the command.

cec_off_policy={poweroff | stayon}

Set or get cec off policy after lpars are powered off. If no cec_off_policy value specified, the cec_off_policy for the nodes will be displayed. The cec_off_policy has two values: poweroff and stayon. poweroff means Power off when last partition powers off. stayon means Stay running after last partition powers off. If cec_off_policy value is specified, the cec off policy will be set for that cec.

HMC_passwd={currentpasswd,newpasswd}

Change the password of the userid HMC for CEC/Frame. If the CEC/Frame is the factory default, the currentpasswd should NOT be specified; otherwise, the currentpasswd should be specified to the current password of the userid HMC for the CEC/Frame.

admin_passwd={currentpasswd,newpasswd}

Change the password of the userid admin for CEC/Frame from currentpasswd to newpasswd. If the CEC/Frame is the factory default, the currentpasswd should NOT be specified; otherwise, the currentpasswd should be specified to the current password of the userid admin for the CEC/Frame.

general_passwd={currentpasswd,newpasswd}

Change the password of the userid general for CEC/Frame from currentpasswd to newpasswd. If the CEC/Frame is the factory default, the currentpasswd should NOT be specified; otherwise, the currentpasswd should be specified to the current password of the userid general for the CEC/Frame.

*_passwd={currentpasswd,newpasswd}

Change the passwords of the userids HMC, admin and general for CEC/Frame from currentpasswd to newpasswd. If the CEC/Frame is the factory default, the currentpasswd should NOT be specified; otherwise, if the current passwords of the userids HMC, admin and general for CEC/Frame are the same one, the currentpasswd should be specified to the current password, and then the password will be changed to the newpasswd. If the CEC/Frame is NOT the factory default, and the current passwords of the userids HMC, admin and general for CEC/Frame are NOT the same one, this option could NOT be used, and we should change the password one by one.

frequency

The NTP update frequency (in minutes).

gard -c|--clear

Clear gard file. [OpenBMC]

garp=time

Get or set Gratuitous ARP generation interval. The unit is number of 1/2 second.

gateway

The gateway ip address.

hostname

Display the CEC/BPA system names.

BSR

Get Barrier Synchronization Register (BSR) allocation for a CEC.

huge_page

Query huge page information or request NUM of huge pages for CEC. If no value specified, it means query huge page information for the specified CECs, if a CEC is specified, the specified huge_page value NUM will be used as the requested number of huge pages for the CEC, if CECs are specified, it means to request the same NUM huge pages for all the specified CECs.

setup_failover={enable | disable}

Enable or disable the service processor failover function of a CEC or display status of this function.

force_failover

Force a service processor failover from the primary service processor to the secondary service processor.

hostname={* | name}

Set CEC/BPA system names to the names in xCAT DB or the input name.

iocap={enable | disable}

Select the policy for I/O Adapter Enlarged Capacity. This option controls the size of PCI memory space allocated to each PCI slot.

hostname

Get or set hostname on the service processor.

vlan

Get or set vlan ID. For get vlan ID, if vlan is not enabled, ‘BMC VLAN disabled’ will be displayed. For set vlan ID, the valid value are [1-4096].

ipsrc

Get the IP source for OpenBMC.

ip

The IP address.

memdecfg={configure | deconfigure:processingunit:unit|bank:id,…}

Select whether each memory bank should be enabled or disabled. State changes take effect on the next platform boot.

netmask

The subnet mask.

powerrestorepolicy

Display or control BMC Power Restore Policy attribute setting. [OpenBMC]

powersupplyredundancy

Display or control BMC Power Supply Redundancy attribute setting. [OpenBMC]

autoreboot

Display or control BMC Auto Reboot attribute setting. [OpenBMC]

bootmode

Display or control BMC Boot Mode attribute setting. [OpenBMC]

dump

Generate/Manage BMC system dumps. If no sub-option is provided, will generate, wait, and download the dump. [OpenBMC]

-c will clear a single specified dump, or use ‘all’ to clear all dumps on the BMC.

-l will list all the generated dumps on the BMC.

-g will generate a new dump on the BMC. Dump generation can take a few minutes.

-d will download a single dump or all generated dumps from the BMC to /var/log/xcat/dump on management or service node.

thermalmode

Display or set the thermal mode of the system to a setting, depending on your system, adapter, and cable type. After a factory reset of the system, the thermal mode setting is lost and must be reapplied. To choose the correct setting for your system, see https://www.ibm.com/support/knowledgecenter/POWER9/p9ei3/p9ei3_thermal_mode.htm [OpenBMC]

timesyncmethod

Set the method for time synchronization on the BMC. [OpenBMC]

network={[ip],[host],[gateway],[netmask]|*}

For MPA: get or set the MPA network parameters. If ‘*’ is specified, all parameters are read from the xCAT database.

For FSP of Flex system P node: set the network parameters. If ‘*’ is specified, all parameters are read from the xCAT database.

initnetwork={[ip],[host],[gateway],[netmask]|*}

For MPA only. Connecting to the IP of MPA from the hosts.otherinterfaces to set the MPA network parameters. If ‘*’ is specified, all parameters are read from the xCAT database.

network={nic,{[ip],[host],[gateway],[netmask]}|*}

Not only for FSP/BPA but also for IMM. Get or set the FSP/BPA/IMM network parameters. If ‘*’ is specified, all parameters are read from the xCAT database. If the value of ip is ‘0.0.0.0’, this nic will be configured as a DHCP client. Otherwise this nic will be configured with a static IP.

Note that IPs of FSP/BPAs will be updated with this option, user needs to put the new IPs to /etc/hosts manually or with xCAT command makehosts. For more details, see the man page of makehosts.

nonred

Allows loss of redundancy.

ntp={[ntpenable],[ntpserver],[frequency],[v3]}

Get or set the MPA Network Time Protocol (NTP) parameters.

ntpenable

Enable or disable NTP (enable|disable).

ntpserver

Get or set NTP server IP address or name.

ntpservers

Get or set NTP servers name. [OpenBMC]

pd1={nonred | redwoperf | redwperf}

Power Domain 1 - determines how an MPA responds to a loss of redundant power.

pd2={nonred | redwoperf | redwperf}

Power Domain 2 - determines how an MPA responds to a loss of redundant power.

procdecfg={configure|deconfigure:processingunit:id,…}

Selects whether each processor should be enabled or disabled. State changes take effect on the next platform boot.

redwoperf

Prevents components from turning on that will cause loss of power redundancy.

redwperf

Power throttles components to maintain power redundancy and prevents components from turning on that will cause loss of power redundancy.

snmpcfg={enable | disable}

Enable or disable SNMP on MPA.

snmpdest=snmpmanager-IP

Get or set where the SNMP alerts should be sent to.

solcfg={enable | disable}

Enable or disable the sol on MPA (or CMM) and blade servers belongs to it.

spdump

Performs a service processor dump.

sshcfg={enable | disable}

Enable or disable SSH on MPA.

sshcfg

Copy SSH keys.

swnet={[ip],[gateway],[netmask]}

Set the Switch network parameters.

sysdump

Performs a system dump.

sysname

Query or set sysname for CEC or Frame. If no value specified, means to query sysname of the specified nodes. If ‘*’ specified, it means to set sysname for the specified nodes, and the sysname values would get from xCAT database. If a string is specified, it means to use the string as sysname value to set for the specified node.

pending_power_on_side={temp|perm}

List or set pending power on side for CEC or Frame. If no pending_power_on_side value specified, the pending power on side for the CECs or frames will be displayed. If specified, the pending_power_on_side value will be set to CEC’s FSPs or Frame’s BPAs. The value ‘temp’ means T-side or temporary side. The value ‘perm’ means P-side or permanent side.

time=hh:mm:ss

Enter the current time in UTC (Coordinated Universal Time) format.

textid={\*|textid}

Set the blade or MPA textid. When using ‘*’, the textid used is the node name specified on the command-line. Note that when specifying an actual textid, only a single node can be specified in the noderange.

USERID={newpasswd} updateBMC={y|n}

Change the password of the userid USERID for CMM in Flex system cluster. The option updateBMC can be used to specify whether updating the password of BMCs that connected to the specified CMM. The value is ‘y’ by default which means whenever updating the password of CMM, the password of BMCs will be also updated. Note that there will be several seconds needed before this command complete.

If value “*” is specified for USERID and the object node is Flex System X node, the password used to access the BMC of the System X node through IPMI will be updated as the same password of the userid USERID of the CMM in the same cluster.

--resetnet

Reset the network interfaces of the specified nodes.

v3

Enable or disable v3 authentication (enable|disable).

-h | --help

Prints out a brief usage message.

-v | --version

Display the version number.

EXAMPLES

  1. To setup new ssh keys on the Management Module mm:

rspconfig mm snmpcfg=enable sshcfg=enable
  1. To turn on SNMP alerts for node5:

rspconfig node5 alert=on

Output is similar to:

node5: Alerts: enabled
  1. To display the destination setting for SNMP alerts for node4:

rspconfig node4 snmpdest

Output is similar to:

node4: BMC SNMP Destination 1: 9.114.47.227
  1. To display the frame number for frame 9A00-10000001

rspconfig> 9A00-10000001 frame

Output is similar to:

9A00-10000001: 1
  1. To set the frame number for frame 9A00-10000001

rspconfig 9A00-10000001 frame=2

Output is similar to:

9A00-10000001: SUCCESS
  1. To set the frame numbers for frame 9A00-10000001 and 9A00-10000002

rspconfig 9A00-10000001,9A00-10000002 frame=*

Output is similar to:

9A00-10000001: SUCCESS
9A00-10000002: SUCCESS
  1. To display the MPA network parameters for mm01:

rspconfig mm01 network

Output is similar to:

mm01: MM IP: 192.168.1.47
mm01: MM Hostname: MM001125C31F28
mm01: Gateway: 192.168.1.254
mm01: Subnet Mask: 255.255.255.224
  1. To change the MPA network parameters with the values in the xCAT database for mm01:

rspconfig mm01 network=*

Output is similar to:

mm01: MM IP: 192.168.1.47
mm01: MM Hostname: mm01
mm01: Gateway: 192.168.1.254
mm01: Subnet Mask: 255.255.255.224
  1. To change only the gateway parameter for the MPA network mm01:

rspconfig mm01 network=,,192.168.1.1,

Output is similar to:

mm01: Gateway: 192.168.1.1
  1. To display the FSP network parameters for fsp01:

rspconfig> fsp01 network

Output is similar to:

fsp01:
       eth0:
               IP Type: Dynamic
               IP Address: 192.168.1.215
               Hostname:
               Gateway:
               Netmask: 255.255.255.0

       eth1:
               IP Type: Dynamic
               IP Address: 192.168.200.51
               Hostname: fsp01
               Gateway:
               Netmask: 255.255.255.0
  1. To change the FSP network parameters with the values in command line for eth0 on fsp01:

rspconfig fsp01 network=eth0,192.168.1.200,fsp01,,255.255.255.0

Output is similar to:

fsp01: Success to set IP address,hostname,netmask
  1. To change the FSP network parameters with the values in the xCAT database for eth0 on fsp01:

rspconfig fsp01 network=eth0,*

Output is similar to:

fsp01: Success to set IP address,hostname,gateway,netmask
  1. To configure eth0 on fsp01 to get dynamic IP address from DHCP server:

rspconfig fsp01 network=eth0,0.0.0.0

Output is similar to:

fsp01: Success to set IP type to dynamic.
  1. To get the current power redundancy mode for power domain 1 on mm01:

rspconfig mm01 pd1

Output is similar to:

mm01: Redundant without performance impact
  1. To change the current power redundancy mode for power domain 1 on mm01 to non-redundant:

rspconfig mm01 pd1=nonred

Output is similar to:

mm01: nonred
  1. To enable NTP with an NTP server address of 192.168.1.1, an update frequency of 90 minutes, and with v3 authentication enabled on mm01:

rspconfig mm01 ntp=enable,192.168.1.1,90,enable

Output is similar to:

mm01: NTP: disabled
mm01: NTP Server: 192.168.1.1
mm01: NTP: 90 (minutes)
mm01: NTP: enabled
  1. To disable NTP v3 authentication only on mm01:

rspconfig mm01 ntp=,,,disable

Output is similar to:

mm01: NTP v3: disabled
  1. To disable Predictive Failure and L2 Failure deconfiguration policies on mm01:

rspconfig mm01 decfg=disable:predictive,L3

Output is similar to:

mm01: Success
  1. To deconfigure processors 4 and 5 of Processing Unit 0 on mm01:

rspconfig mm01 procedecfg=deconfigure:0:4,5

Output is similar to:

mm01: Success
  1. To check if CEC sysname set correct on mm01:

rspconfig mm01 sysname

mm01: mm01

rspconfig mm01 sysname=cec01

mm01: Success

rspconfig mm01 sysname

mm01: cec01
  1. To check and change the pending_power_on_side value of cec01’s fsps:

rspconfig cec01 pending_power_on_side

cec01: Pending Power On Side Primary: temp
cec01: Pending Power On Side Secondary: temp

rspconfig cec01 pending_power_on_side=perm

cec01: Success

rspconfig cec01 pending_power_on_side

cec01: Pending Power On Side Primary: perm
cec01: Pending Power On Side Secondary: perm
  1. To show the BSR allocation for cec01:

rspconfig cec01 BSR

Output is similar to:

cec01: Barrier Synchronization Register (BSR)
cec01: Number of BSR arrays: 256
cec01: Bytes per BSR array : 4096
cec01: Available BSR array : 0
cec01: Partition name: BSR arrays
cec01: lpar01        : 32
cec01: lpar02        : 32
cec01: lpar03        : 32
cec01: lpar04        : 32
cec01: lpar05        : 32
cec01: lpar06        : 32
cec01: lpar07        : 32
cec01: lpar08        : 32
  1. To query the huge page information for CEC1, enter:

rspconfig CEC1 huge_page

Output is similar to:

CEC1: Huge Page Memory
CEC1: Available huge page memory(in pages):    0
CEC1: Configurable huge page memory(in pages): 12
CEC1: Page Size (in GB):                       16
CEC1: Maximum huge page memory(in pages):      24
CEC1: Requested huge page memory(in pages):    15
CEC1: Partition name: Huge pages
CEC1: lpar1         : 3
CEC1: lpar5         : 3
CEC1: lpar9         : 3
CEC1: lpar13        : 3
CEC1: lpar17        : 0
CEC1: lpar21        : 0
CEC1: lpar25        : 0
CEC1: lpar29        : 0
  1. To request 10 huge pages for CEC1, enter:

rspconfig CEC1 huge_page=10

Output is similar to:

CEC1: Success
  1. To disable service processor failover for cec01, in order to complete this command, the user should power off cec01 first:

rspconfig cec01 setup_failover

cec01: Failover status: Enabled

rpower cec01 off

rspconfig cec01 setup_failover=disable

cec01: Success

rspconfig cec01 setup_failover

cec01: Failover status: Disabled
  1. To force service processor failover for cec01:

lshwconn cec01

cec01: 192.168.1.1: LINE DOWN
cec01: 192.168.2.1: sp=primary,ipadd=192.168.2.1,alt_ipadd=unavailable,state=LINE UP
cec01: 192.168.1.2: sp=secondary,ipadd=192.168.1.2,alt_ipadd=unavailable,state=LINE UP
cec01: 192.168.2.2: LINE DOWN

rspconfig cec01 force_failover

cec01: Success.

lshwconn> cec01

cec01: 192.168.1.1: sp=secondary,ipadd=192.168.1.1,alt_ipadd=unavailable,state=LINE UP
cec01: 192.168.2.1: LINE DOWN
cec01: 192.168.1.2: LINE DOWN
cec01: 192.168.2.2: sp=primary,ipadd=192.168.2.2,alt_ipadd=unavailable,state=LINE UP
  1. To deconfigure memory bank 9 and 10 of Processing Unit 0 on mm01:

rspconfig mm01 memdecfg=deconfigure:bank:0:9,10

Output is similar to:

mm01: Success
  1. To reset the network interface of the specified nodes:

rspconfig --resetnet

Output is similar to:

Start to reset network..

Reset network failed nodes:

Reset network succeed nodes:
Server-8233-E8B-SN1000ECP-A,Server-9119-FHA-SN0275995-B,Server-9119-FHA-SN0275995-A,

Reset network finished.
  1. To update the existing admin password on fsp:

rspconfig fsp admin_passwd=admin,abc123

Output is similar to:

fsp: Success
  1. To set the initial password for user HMC on fsp:

rspconfig fsp HMC_passwd=,abc123

Output is similar to:

fsp: Success
  1. To list BMC dumps available for download:

rspconfig p9euh02 dump -l

Output is similar to:

p9euh02: [1] Generated: 09/06/2017 14:31:49, Size: 4528
p9euh02: [2] Generated: 09/06/2017 14:31:55, Size: 4516
p9euh02: [3] Generated: 09/06/2017 14:32:01, Size: 4236
p9euh02: [4] Generated: 09/06/2017 14:32:07, Size: 4248
p9euh02: [5] Generated: 09/06/2017 14:32:11, Size: 4268
  1. To generate and download BMC dump:

rspconfig p9euh02 dump

Output is similar to:

Capturing BMC Diagnostic information, this will take some time...
p9euh02: Dump requested. Target ID is 6, waiting for BMC to generate...
p9euh02: Dump 6 generated. Downloading to /var/log/xcat/dump/20171211-0951_p9euh02_dump_6.tar.xz

SEE ALSO

noderange(3)|noderange.3, rpower(1)|rpower.1, rcons(1)|rcons.1, rinv(1)|rinv.1, rvitals(1)|rvitals.1, rscan(1)|rscan.1, rflash(1)|rflash.1