mkhwconn.1

NAME

mkhwconn - Sets up connections for CEC and Frame nodes to HMC nodes or hardware server.

SYNOPSIS

mkhwconn [-h| --help]

mkhwconn [-v| --version]

PPC (with HMC) specific:

mkhwconn [-V| --verbose] noderange -t [--port port_value]

mkhwconn [-V| --verbose] noderange -s [hmcnode --port port_value]

mkhwconn [-V| --verbose] noderange -p hmc [-P passwd] [--port port_value]

PPC (using Direct FSP Management) specific:

mkhwconn noderange -t [-T tooltype] [--port port_value]

DESCRIPTION

For PPC (with HMC) specific:

This command is used to set up connections for CEC and Frame nodes to HMC nodes. (If the connection already exists, it will not break it.) This command is useful when you have multiple HMCs, each of which will manage a subset of the CECs/Frames. Use mkhwconn to tell each HMC which CECs/Frames it should manage. When using this, you should turn off the self-discovery on each HMC. You also need to put all the HMCs and all the Frames on a single flat service network.

When -t is specified, this command reads the connection information from the xCAT ppc table (e.g. the parent attribute), and read the user/password from the ppcdirect table. Then this command will assign CEC nodes and Frame nodes to HMC nodes.

When -p is specified, this command gets the connection information from command line arguments. If -P is not specified, the default password for CEC and Frame nodes is used.

The flag -s is used to make the connection between the frame and its Service focal point(HMC). Makehwconn will also set the connections between the CECs within this Frame and the HMC. The sfp of the frame/CEC can either be defined in ppc table beforehand or specified in command line after the flag -s. If the user use mkhwconn noderange -s HMC_name, it will not only make the connections but also set the sfp attributes for these nodes in PPC table.

In any case, before running this command, the CEC and Frame nodes need be defined with correct nodetype.nodetype value (cec or frame) and nodehm.mgt value (hmc).

Note: If a CEC belongs to a frame, which has a BPA installed, this CEC should not be assigned to an HMC individually. Instead, the whole frame should be assigned to the HMC.

For PPC (using Direct FSP Management) specific:

It is used to set up connections for CEC and Frame node to Hardware Server on management node (or service node ). It only could be done according to the node definition in xCAT DB. And this command will try to read the user/password from the ppcdirect table first. If fails, then read them from passwd table. Commonly , the username is HMC. If using the ppcdirect table, each CEC/Frame and user/password should be stored in ppcdirect table. If using the passwd table, the key should be “cec“ or “frame“, and the related user/password are stored in passwd table.

When --port is specified, this command will create the connections for CECs/Frames whose side in vpd table is equal to port value.

OPTIONS

-h|--help

Display usage message.

-t

Read connection information from xCAT DB (ppc and ppcdirect tables). Use this option if you need to connect multiple CECs/Frames to multiple HMCs in a single command.

-p

The HMC node name. Only one HMC nodes can be specified by this flag. To setup connection for multiple HMC nodes, use flag -t.

-P

The password of HMC based CEC/Frame login user(Default user name is ‘HMC’). This flag is optional.

-T

The tooltype is used to communicate to the CEC/Frame. The value could be lpar or fnm. The tooltype value lpar is for xCAT and fnm is for CNM. The default value is “lpar“.

--port

The port value specifies which special side will be used to create the connection to the CEC/Frame. The value could only be specified as “0“ or “1“ and the default value is “0,1“. If the user wants to use all ports to create the connection, he should not specify this value. If the port value is specified as “0“, in the vpd table, the side column should be A-0 and B-0; If the port value is specified as “1“, the side column should be A-1 and B-1. When making hardware connection between CEC/Frame and HMC, the value is used to specify the fsp/bpa port of the cec/frame and will be organized in order of “A-0,A-1,B-0,B-1“. If any side does not exist, the side would simply be ignored. Generally, only one port of a fsp/bap can be connected while another port be used as backup.

-s

The flag -s is used to make the connection between the frame and its Service Focal Point(HMC). -s flag is not supposed to work with other functional flags.

-V|--verbose

Verbose output.

RETURN VALUE

0 The command completed successfully.

1 An error has occurred.

EXAMPLES

  1. To setup the connection for all CEC nodes in node group cec to HMC node, according to the definition in xCAT DB:

    mkhwconn cec -t
    
  2. To setup the connection for Frame nodes in node group frame to HMC node hmc1, with password ‘abc123’:

    mkhwconn frame -p hmc1 -P abc123
    
  3. To setup the connections for all CEC nodes in node group cec to hardware server, and the tooltype value is lpar:

    mkhwconn cec -t -T lpar
    
  4. To setup the connections for all cecs nodes in node group cec to hardware server, and the tooltype value is lpar, and the port value is 1:

    mkhwconn cec -t -T lpar --port 1
    
  5. To setup the connection between the frame and it’s SFP node. This command will also set the connections between the CECs within this frame and their SFP node. User need to define HMC_name in the database in advance, but no need to set the sfp attribute for these node, xCAT will set the HMC_name as ppc.sfp for these nodes. The CECs within this frame should have the same sfp attribute as the frame.

    mkhwconn cec -s HMC_name -P HMC_passwd
    

FILES

$XCATROOT/bin/mkhwconn

(The XCATROOT environment variable is set when xCAT is installed. The default value is “/opt/xcat”.)

NOTES

This command is part of the xCAT software product.

SEE ALSO

lshwconn(1)|lshwconn.1, rmhwconn(1)|rmhwconn.1